DIN EN 60352 2 PDF

Overview. DIN EN includes requirements, tests and practical guidance information for solderless crimped connections made with stranded wires of 0,05 . DIN EN Solderless connections – Part 2: Crimped connections – General requirements, test methods and practical guidance (IEC. IEC Standard | Solderless connections – Part 2: Crimped connections – General requirements, test methods and practical.

Author: Moogudal Yozshurn
Country: Denmark
Language: English (Spanish)
Genre: Sex
Published (Last): 3 July 2013
Pages: 284
PDF File Size: 10.39 Mb
ePub File Size: 11.77 Mb
ISBN: 141-3-70903-678-4
Downloads: 88965
Price: Free* [*Free Regsitration Required]
Uploader: Sazshura

If the document is revised or amended, you will be notified by email. In addition to cable assemblies, we offer system cables and a wide range of distribution boxes.

Add to Alert PDF. Solderless non-accessible insulation displacement connections Terms and Conditions Terms of subscription Online watch. Interviews Manufacturing processes are changing “I need transformation, not change.

DIN EN 60352 2 PDF

The consequence of this is sn better crimping results and variable applications. Solderless non-accessible insulation displacement connections Quality — Security — Environment.

Din en 2 handling equipment Cin standards translated into French. The quality tool impresses due to its particularly efficient and secure crimping with just one tool – it makes the work easier, even in sin places or in confined cabinets. Details This part of IEC is applicable to solderless crimped connections made with stranded wires din en 2 0,05 mm2 to 10 mm2 cross-section or solid wires of 0,25 mm to 3,6 mm diameter and appropriately designed uninsulated or pre-insulated crimp barrels for use enn telecommunication equipment and in electronic devices employing similar techniques.

This is a Solution page 60325 show you the all paragraph types, which are available for this content type. There are large numbers of tools and tooling systems for the respective product groups. This eliminates the need for the idn changing of the tool, as the “PZ 6 Roto L” can be used to crimp cables and wire-end ferrules in a cross-section range of 0.

IEC | IEC Webstore

Electoral Code — Presidential and Legislative Elections Interfaces are the input output paths of information of a device. The fixed locking mechanisms prevent the crimp insert from being accidentally rotated during the crimping process. Nonelectronic Parts Reliability Data Publication Packaging and distribution of goods Uncertainty of measurement and test results. Accounting, Social and Fiscal: Legal notices Photo credits FAQ. We have no document history for this standard.

Try This PDF:   ASKEP HNP EBOOK DOWNLOAD

Please first verify your email before subscribing to alerts. When applying this technology, a terminating pin is centred through a metallized hole into a circuit board. Data, signals and power can be easily connected and locked. Test yourself or your business online.

Since the contacts are equipped with deformable elastic press-in zones at vin positions an optimal connection is processed by pressing-in the contact into the PCB hole. Choice of language German Choice of format.

This standard is applicable to solderless crimped connections made with stranded wires of 0,05 mm2 to 10 mm2 cross-section or solid wires of enn mm to 3,6 mm fn and appropriately designed uninsulated or pre-insulated crimp barrels for use in telecommunication equipment and in electronic devices employing similar techniques. Skip to content You are here: Register online at inter and intra-company training, and certifying diplomas, seminars, distance learning.

You may delete a document from your Alert Profile at any time. The design, material and surface structure of the handles make professional tool use easier in industry or manual trades and ensure safe, comfortable operation.

Your Alert Profile lists the documents that will be monitored. Benefits of the crimping technique: Crimped connections — General requirements, test methods and practical guidance IEC. Networks in modern production facilities idn becoming increasingly complex.

Insulation displacement connectors IDC for short are ideal solution for device manufacturers if two or more PCBs are to be connected across longer distances. The consequence of this is markedly better crimping results and variable applications. Become exhibitor Online Application. Company organization, management and quality. Crimped connections — General requirements, test methods and practical guidance IEC.

The crimping of wire-end ferrules not only requires manual dexterity, but also a suitable crimping tool and the matching contacts. The “PZ 6 Roto L” all-rounder allows users to feed the lines and wire-end ferrules either from the front or side into the tool, which significantly reduces the effort involved. Budget and Community Finances JavaScript seems to be disabled in your browser.

Try This PDF:   LIBRO ESTA PATENTE OSCURIDAD EBOOK

All these tools process produce crimp connections of a consistent high quality meeting the relevant standard for this area, the DIN EN Discover also Certification, assessment, diagnosis Get a quote for certification of systems, products or services, and get certified. Civil status — Town halls and communities. With har-port, HARTING offers a sophisticated and visually appealing system for service interfaces on industrial dn, switch cabinets, medical and building technology.

Din en 2 object of this part of IEC is to determine the suitability of solderless crimped connections under specified mechanical, electrical and atmospheric conditions and to provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture. The “PZ 6 Roto L” combines an adjustable crimp insert with a fixed locking mechanism for the very first time.

Particularly efficient and secure crimping – with just one crimping tool

Select the first category of products searched and follow the instructions. Added to this is the ease of processing at the highest level: The “PZ 6 roto L” is particularly suited to small and medium series in the service and repair sector.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Based on our complete HARTING connectivity dim, din en 2 design customised cable assemblies to match your requirements and transform standardised housings into tailor-made solutions for your company.

This standard is not included in any packages.